I am thinking about this wood burner as an addon to my gas fired furnace. What modifications would need to be made to accommodate my system; i.e. cold air return and what is the mandatory size smoke effluent pipe needed?
Posted by Elite Deals - Chris M. on 28 October 2013 12:57 PM

Our Answer:

In order to use this unit in conjunction with an existing furnace, it must be located in close proximity and duct its outflow into the plenum for the furnace. This is done by using a pair of 8 inch supply ducts. Cold air will need to be supplied from the return plenum at the base of the furnace. This can be done by using the available filter box or by fabricating a return duct to the base of the unit. A 6" chimney system can be used for this unit. Standard 6 inch chimney connector (stove pipe) can be run to the first combustible wall or ceiling, then converted to Class A chimney for the remainder of the run. Class A chimney can be used from the unit as well, for longevity purposes.

From Page: US Stove Hotblast Wood Burning Furnace with Twin Blowers - 1400

Manufacturer's Product Number: 1400

Our SKU: USS-1400

Page ID: uss-1400