Live Chat Software by Kayako |
I recently installed the 24" Real Fyre English Oak Vented Gas Log Set. After much trying I got the set to light with the remote only one time, but not again. I have changed the batteries in both remote items and it still won't light. I carefully 'learned
Posted by Elite Deals - Chris M. on 28 October 2013 01:12 PM
|
|
Our Answer: The next step to troubleshoot the issue involves checking voltage output from the remote receiver. Using a voltage tester, touch the probes to the pair of output connections on the back of the receiver. Push the on button on the remote. The voltage tester should read approximately 6 volts. If it does not, either the receiver or remote is bad and a replacement will be needed. If the receiver does output 6 volts, double check all wiring connections to be sure they are tight and routed properly. If they are, the valve motor may be bad and a replacement will be needed. In Response to Question: I recently installed the 24" Real Fyre English Oak Vented Gas Log Set. After much trying I got the set to light with the remote only one time, but not again. I have changed the batteries in both remote items and it still won't light. I carefully 'learned' the handset, but it didn't help. What do I do now? From Page: Peterson Real Fyre Charred Royal English Oak Vented Gas Log Set - Natural Gas - 24" Manufacturer's Product Number: CHBG45-24 Our SKU: PTS-CHBG45-24 Page ID: perefychrooa4 | |
|