I have two Real Fyre propane sets. How can I convert them to natural gas?
Posted by Elite Deals - Chris M. on 24 October 2013 03:28 PM

Our Answer:

Converting a Peterson Real Fyre log set from Propane to Natural gas only requires the swapping out of the Air Mixer on the burner for a Fuel Injector. As well as the replacement of the Vermiculite ember fill with Peterson Select Sand (PTS-CS-10). If you are interested in continuing to use a control valve, you'll need to replace the pilot orifice in that valve's pilot assembly. Each size log set requires a different size Fuel Injector.