Hello, I have a 7" ID clay thimble surrounded by about 8" of brick, It's my understanding that the brick should have been 12" clearance all around the thimble. Could I use this piece of double wall stovepipe masonry adaptor instead of tearing my wall a
Posted by Elite Deals - Chris M. on 24 October 2013 03:28 PM

Our Answer:

This adaptor is designed for use with our Selkirk DSP Double-Wall stove pipe. This Double-Wall pipe only requires a 6" clearance to combustibles. As such, your 8" of brick would be sufficient. However, if you are intending to use Single-Wall pipe, 18" of clearance to combustibles must be maintained.

In Response to Question:

Hello, I have a 7" ID clay thimble surrounded by about 8" of brick, It's my understanding that the brick should have been 12" clearance all around the thimble. Could I use this piece of double wall stovepipe masonry adaptor instead of tearing my wall apart to try to extend the brick from 8" to 12"? The depth from the face of the thimble to the inside off the chimney is 12"'